Pure Transfer is proud to introduce a new technology that enables the use of a self contained biological indicator in sanitary process lines. This unique Rubber Fab Smart Gasket® permits either top loading or inline positioning of the EZTest self contained biological indicator and/or temperature probe.
The great advantage of a self contained biological indicator over the traditional spore strip in glassine is the time saved when confirming spore kill. Results are easily obtained in only 24 hours (versus the 5 to 7 days required with a spore strip).
You can feel secure knowing that the biological indicator will not be lost down stream in the process. The fail-safe Rubber Fab Smart Gasket® holds the indicator in place for easy retrieval. Available for 3/4'', 1.0'', 1.5'' and 2.0'' Sanitary, Tri-Clamp process lines.
-
Biological Indicator Gasket Part Numbers (*Biological indicator gaskets with Smart port end in -1.) Part Number Gasket O.D. Gasket I.D. Bead 42RXPX-BI-075 0.86" 0.62" NA *42RXPX-BI-075-1 0.86" 0.62" NA 40RXPX-BI-100 1.984" 0.9" 1.718" *40RXPX-BI-100-1 1.984" 0.9" 1.718" 40RXPX-BI-150 1.984" 1.4" 1.718" *40RXPX-BI-150-1 1.984" 1.4" 1.718" 40RXPX-BI-200 2.515" 1.9" 2.218" *40RXPX-BI-200-1 2.515" 1.9" 2.218"